TÆKNILEGAR UPPLÝSINGAR

◆Power supply: DC 9V battery, 6F22 (1 year life)
◆Standby current: Less than or equal to 15uA
◆Alarm current: Less than or equal to 45mA
◆Alarm sound: Greater than or equal to 85dB (3m)
◆Sensor type: Photoelectric
◆Low battery warning: <>
◆Temperature range: 0 degree 49 degree (32 degree F120 degree F)
◆Humidity: Less than or equal to 95 percent RH (No icing or condensation)
◆Detecting area: 60m²at installation height <>
◆Dimension:Φ100(D) x 36.2(H)mm
◆Executive criteria: EN 14604:2005
EIGINLEIKAR
◆Advanced photoelectric sensing technology
◆Low-battery warning
◆Simplicity and elegance
◆SMT manufacture technology: high quality and reliability
◆Test button for battery and alarm operation verification, Test button; tests unit's electronic circuitry, buzzer and battery function. Hush function.
◆Loud alarm signal exceeding 85dB in alarm mode
◆Easy installation and maintenance
◆Auto check malfunction.
◆Low battery warning; smoke alarm will chirp once every 50s to remind user of replacing a new battery.
◆Auto reset
◆ Sound and flash alarm; alarm sound louder than 85 decibels with red LED flashing.
◆ Dustproof, mothproof and anti-white light interference design. ◆Anti-RFI (20V/m-1GHz).
UPPSETNING
Avoid installations in places with stagnating smoke, heavy dust, heavy water mist, heavy oil mist, great humidity (>95%) and high wind speed (>5m/s)
Choose a proper position. Normally the center of the detection area ceiling is recommended. If impractical, do not install the detector in area without air flow For roof with oblique beam, the ceiling is also oblique where the detector should be installed at a position with 0.9m horizontal distance to spire. Fix the detector base into a chosen position with screws. Then put the detector head into the base and twist clockwise to fasten it Installation dimension of bracket:

REKSTRI LEIÐBEININGAR
1. Battery is equipped on delivery. Test it before install it.
2. The smoke alarm enters into normal monitoring status. The LED blinks once every 50s.
3. Sensitivity Test To ensure normal operation, periodic tests should be performed. Once a month is recommended. For testing, press and hold the test button more than 3s to enter into sensitivity test status. The alarm indicator will flash rapidly and buzzer will give out alarm sound, which indicates the smoke alarm works properly. During testing, keep ears away from the smoke alarm to avoid hearing damage.
4. Malfunction Check When buzzer beeps once every 50s along with alarm indicator flashing once rapidly, the battery voltage is lower than normal operating voltage for the smoke alarm. Replace the battery. When buzzer beeps twice (di di) every 50s without alarm indicator flashing, the infrared photoelectric sensor has malfunction. For this situation, contact the vendor on time. Do not dismount or repair alarms privately to avoid accidents.
5. Detector Replacement When smoke alarms come into malfunction or have low battery warning, please replace the smoke detector or change the battery immediately.
TILKYNNING
1. The malfunction auto check function of this smoke alarm only provides infrared photoelectric sensor malfunction check and low battery power check. The sensor sensitivity should be tested periodically as required.
2. To ensure the sensitivity to smoke, clean the smoke alarm surface with soft brush or cleaner every 6 months. Do not use solvent, liquid or detergent to clean the smoke alarm.
3. For malfunction problems, please contact vendor on time. Do not dismantle and try to repair alarms privately.
4. Photoelectric smoke alarms could reduce disaster happening, but they cannot guarantee 100 percent safety. For your safety concern, please use this smoke alarm correctly and know the fire safety tips. In daily life, pay attention to build up safety consciousness and take preventive measures.
ELD ÖRY&I
Follow fire safety rules and prevent hazardous situations:
1. Store combustible liquids such as gasoline in proper containers.
2. Never smoke in bed. After smoking a cigarette, put it out and place in a correct container.
3. Check if power sockets, plugs or switches are broken. If cables are frayed or cracked, replace them on time.
4. Using power electric appliances such as heaters or heating equipment, do not make the circuit overload and check periodically if these appliances work properly.
5. Keep portable heaters and open flames, like candles, away from flammable materials.
6. Keep matches or lighters away from children.
7. Keep at least one working fire extinguisher on every floor and an additional one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked.
8. Make sure all the family members know what to do after hearing an alarm signal
9. Install smoke alarms correctly according to manual. Keep alarms clean and do not let dust accumulate and test them monthly. Replace them immediately if they are not working properly.
PÖKKUNARLISTI
1. smoke alarm 1 pcs
2. installation bracket 1pcs
3. instruction manual 1pcs
4. 9V (6F22) battery 1 pcs
5. installation screw 2 pcs
6. plaströr hvert 2 stk